Evaluation of a Novel Culture System for Rapid Pathogen Identification and Detection of Cephalosporin Resistance in Neonatal Gram-negative Sepsis at a Tertiary Referral Unit in Harare, Zimbabwe.

GwendolineChimhini; Ioana Diana Olaru ORCID logo; FelicityFitzgerald; MutsawasheChisenga; CeciliaFerreyra; NadaMalou; JeremiePiton; SimbarasheChimhuya; Shunmay Yeung ORCID logo; SurjoDe; +2 more... Hilda AMujuru; Katharina Kranzer ORCID logo; (2021) Evaluation of a Novel Culture System for Rapid Pathogen Identification and Detection of Cephalosporin Resistance in Neonatal Gram-negative Sepsis at a Tertiary Referral Unit in Harare, Zimbabwe. The Pediatric infectious disease journal, 40 (9). pp. 785-791. ISSN 0891-3668 DOI: 10.1097/INF.0000000000003155
Copy

BACKGROUND: Neonatal sepsis accounts for a large proportion of neonatal deaths in sub-Saharan Africa. The lack of access to diagnostic testing and excessively long turnaround times to result contributes to delays in sepsis identification and initiation of appropriate treatment. This study aims to evaluate the novel InTrays COLOREX Screen and extended-spectrum beta-lactamase for rapid identification of bacterial pathogens causing sepsis and detection of resistance. METHODS: Neonates with suspected sepsis admitted to the Harare Central Hospital were prospectively enrolled. One blood culture was collected and incubated using the BacT/ALERT automated system. Positive blood cultures with potential pathogens identified by Gram stain were inoculated on the InTray COLOREX Screen and extended-spectrum beta-lactamase culture plates. RESULTS: A total of 216 neonates with suspected sepsis were recruited. Pathogens were isolated from blood cultures in 56 (25.9%) neonates of which 54 were Klebsiella pneumoniae. All K. pneumoniae were resistant to ceftriaxone and 53 (98%) were resistant to gentamicin. Sensitivity and specificity for ceftriaxone-resistant K. pneumoniae detection using InTrays were 100%. InTrays results were interpretable as early as 5-10 hours (median 7 hours, interquartile range 7-7) post blood culture positivity enabling rapid identification and notification of result and leading to a 60% reduction in time to result from blood culture collection. CONCLUSIONS: This study shows that the implementation of a novel culture method was feasible and reduced turnaround times for results by 60% compared with standard microbiologic techniques. An impact on patient outcomes and cost-effectiveness of this method needs to be demonstrated.



picture_as_pdf
Chimhini_etal_2021_Evaluation-of-a-novel-culture.pdf
subject
Accepted Version
Available under Creative Commons: NC-ND 3.0

View Download
picture_as_pdf

Supplemental Material


Explore Further

Read more research from the creator(s):

Find work associated with the faculties and division(s):

Find work associated with the research centre(s):

Find work from this publication: