Accuracy of the smartphone-based nonmydriatic retinal camera in the detection of sight-threatening diabetic retinopathy.

Vijayaraghavan Prathiba; Ramachandran Rajalakshmi; Subramaniam Arulmalar; Manoharan Usha; Radhakrishnan Subhashini; Clare E Gilbert ORCID logo; Ranjit Mohan Anjana; Viswanathan Mohan; (2020) Accuracy of the smartphone-based nonmydriatic retinal camera in the detection of sight-threatening diabetic retinopathy. INDIAN JOURNAL OF OPHTHALMOLOGY, 68 (Suppl). S42-S46. ISSN 0301-4738 DOI: 10.4103/ijo.IJO_1937_19
Copy

PURPOSE: To evaluate the sensitivity and specificity of smartphone-based nonmydriatic (NM) retinal camera in the detection of diabetic retinopathy (DR) and sight-threatening DR (STDR) in a tertiary eye care facility. METHODS: Patients with diabetes underwent retinal photography with a smartphone-based NM fundus camera before mydriasis and standard 7-field fundus photography with a desktop mydriatic fundus camera after mydriasis. DR was graded using the international clinical classification of diabetic retinopathy system by two retinal expert ophthalmologists masked to each other and to the patient's identity. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) to detect DR and STDR by NM retinal imaging were assessed. RESULTS: 245 people had gradable images in one or both eyes. DR and STDR were detected in 45.3% and 24.5%, respectively using NM camera, and in 57.6% and 28.6%, respectively using mydriatic camera. The sensitivity and specificity to detect any DR by NM camera was 75.2% (95% confidence interval (CI) 68.1-82.3) and 95.2% (95%CI 91.1-99.3). For STDR the values were 82.9% (95% CI 74.0-91.7) and 98.9% (95% CI 97.3-100), respectively. The PPV to detect any DR was 95.5% (95% CI 89.8-98.5) and NPV was 73.9% (95% CI 66.4-81.3); PPV for STDR detection was 96.7% (95% CI 92.1-100)) and NPV was 93.5% (95% CI 90.0-97.1). CONCLUSION: Smartphone-based NM retinal camera had fairly high sensitivity and specificity for detection of DR and STDR in this clinic-based study. Further studies are warranted in other settings.


picture_as_pdf
IndianJOphthalmol681342-4414789_121547.pdf
subject
Published Version
Available under Creative Commons: NC-ND 3.0

View Download

Atom BibTeX OpenURL ContextObject in Span Multiline CSV OpenURL ContextObject Dublin Core Dublin Core MPEG-21 DIDL EndNote HTML Citation JSON MARC (ASCII) MARC (ISO 2709) METS MODS RDF+N3 RDF+N-Triples RDF+XML RIOXX2 XML Reference Manager Refer Simple Metadata ASCII Citation EP3 XML
Export

Downloads