Effect of intraocular lens edge profile on posterior capsule opacification after extracapsular cataract surgery in a developing country.

Alpesh Shah; David J Spalton; Clare Gilbert ORCID logo; Abhay Vasavada; James F Boyce; Darwin Minassian; Hari Jayaram; Denise Mabey ORCID logo; (2007) Effect of intraocular lens edge profile on posterior capsule opacification after extracapsular cataract surgery in a developing country. Journal of cataract and refractive surgery, 33 (7). pp. 1259-1266. ISSN 0886-3350 DOI: 10.1016/j.jcrs.2007.03.044
Copy

PURPOSE: To determine whether square-edged polymethyl methacrylate (PMMA) intraocular lenses (IOLs) reduce posterior capsule opacification (PCO) in the context of extracapsular cataract surgery in a developing country. SETTING: A rural hospital in India. METHODS: This was a prospective randomized double-masked fellow-eye controlled study. Over a 4-month period, 118 patients with normal eyes apart from age-related cataract were randomized to receive a square-edged or round-edged PMMA IOL in the first eye. The IOLs were identical apart from the edge profile. The fellow-eye had implantation of the alternative IOL within 1 month. Retroillumination images of the posterior capsule were taken using a dedicated camera system and analyzed to quantify the PCO area using POCO software 1 and 2 years postoperatively and the PCO area and severity using POCOman semiqualitative software at 2 years. Visual acuity was measured using a Gujarati logMAR chart. RESULTS: One hundred fifteen patients were available for examination at 1 year and 107 at 2 years. With POCO software, the PCO area was reduced in the square-edged IOL group at 1 year (median 30% versus 20%, P=.001) and at 2 years (median 45% versus 35%, P=.006). With POCOman, the PCO area and severity were reduced in the square-edged group at 2 years (median 41.5% versus 33.2%, P=.019 and 0.59 versus 0.46, P=.037, respectively). There was no significant difference in visual acuity between the 2 groups at 1 or 2 years. CONCLUSIONS: Sophisticated image analysis techniques can be used in developing countries to quantify PCO. Using extracapsular surgery, square-edged PMMA IOLs reduced the PCO area and severity compared with an identical round-edged IOL; however, the differences were not as marked as those reported with phacoemulsification. This may be due to the difficulty of performing a capsulorhexis that lies on the IOL surface in this situation. Nevertheless, square-edged IOLs offer a potential benefit for extracapsular surgery in the developing world.

Full text not available from this repository.

Atom BibTeX OpenURL ContextObject in Span Multiline CSV OpenURL ContextObject Dublin Core Dublin Core MPEG-21 DIDL EndNote HTML Citation JSON MARC (ASCII) MARC (ISO 2709) METS MODS RDF+N3 RDF+N-Triples RDF+XML RIOXX2 XML Reference Manager Refer Simple Metadata ASCII Citation EP3 XML
Export

Downloads