Evaluating the Interrater Agreement and Acceptability of a New Reference Tool for Assessing Respiratory Rate in Children under Five with Cough and/or Difficulty Breathing.

Ann-Sophie Stratil ORCID logo; Charlotte Ward ORCID logo; Tedila Habte ORCID logo; Alice Maurel ORCID logo; MaxAntson; Elina Naydenova ORCID logo; Kevin Baker ORCID logo; (2021) Evaluating the Interrater Agreement and Acceptability of a New Reference Tool for Assessing Respiratory Rate in Children under Five with Cough and/or Difficulty Breathing. Journal of Tropical Pediatrics, 67 (2). fmab046-. ISSN 0142-6338 DOI: 10.1093/tropej/fmab046
Copy

BACKGROUND: Manual assessment of respiratory rate (RR) in children is unreliable, but remains the main method to diagnose pneumonia in low-resource settings. While automated RR counters offer a potential solution, there is currently no gold standard to validate these diagnostic aids. A video-based reference tool is proposed that allows users to annotate breaths and distortions including movement periods, allowing the exclusion of distortions from the computation of RR measures similar to how new diagnostic aids account for distortions automatically. This study evaluated the interrater agreement and acceptability of the new reference tool. METHODS: Annotations were based on previously recorded reference videos of children under five years old with cough and/or difficulty breathing (n = 50). Five randomly selected medical experts from a panel of ten annotated each video. RR measures (breaths per minute, bpm) were computed as the number of annotated certain breaths divided by the length of calm periods after removing annotated distorted periods. RESULTS: Reviewers showed good interrater agreement on continuous RR {standard error of measurement (SEM) [4.8 (95%CI 4.4-5.3)]} and substantial agreement on classification of fast breathing (Fleiss kappa, κ 0.71). Agreement was lowest in the youngest age group [< 2 months: SEM 6.2 (5.4-7.4) bpm, κ 0.48; 2-11 months: 4.7 (4.0-5.8) bpm, κ 0.84; 12-59 months: 2.6 (2.2-3.1) bpm, κ 0.8]. Reviewers found the functionalities of the tool helpful in annotating breaths, but remained uncertain about the validity of their annotations. CONCLUSIONS: Before the new tool can be considered a reference standard for RR assessments, interrater agreement in children younger than 2 months must be improved.



picture_as_pdf
Stratil_etal_2021_Evaluating-the-interrater-agreement-and.pdf
subject
Published Version
Available under Creative Commons: 3.0

View Download

Explore Further

Read more research from the creator(s):

Find work associated with the faculties and division(s):

Find work from this publication: