Clinical utility of existing and second-generation interferon-γ release assays for diagnostic evaluation of tuberculosis: an observational cohort study.

Hilary S Whitworth ORCID logo; Amarjit Badhan; Aime A Boakye; Yemisi Takwoingi; Melanie Rees-Roberts; Christopher Partlett; Heather Lambie; John Innes; Graham Cooke; Marc Lipman; +10 more... Christopher Conlon; Derek Macallan; Felix Chua; Frank A Post; Martin Wiselka; Gerrit Woltmann; Jonathan J Deeks; Onn Min Kon; Ajit Lalvani; Interferon-γ Release Assays for Diagnostic Evaluation of Active ; (2019) Clinical utility of existing and second-generation interferon-γ release assays for diagnostic evaluation of tuberculosis: an observational cohort study. Lancet Infectious Diseases, 19 (2). pp. 193-202. ISSN 1473-3099 DOI: 10.1016/S1473-3099(18)30613-3
Copy

BACKGROUND: The clinical utility of interferon-γ release assays (IGRAs) for diagnosis of active tuberculosis is unclear, although they are commonly used in countries with a low incidence of tuberculosis. We aimed to resolve this clinical uncertainty by determining the accuracy and utility of commercially available and second-generation IGRAs in the diagnostic assessment of suspected tuberculosis in a low-incidence setting. METHODS: We did a prospective cohort study of adults with suspected tuberculosis in routine secondary care in England. Patients were tested for Mycobacterium tuberculosis infection at baseline with commercially available (T-SPOT.TB and QuantiFERON-TB Gold In-Tube [QFT-GIT]) and second-generation (incorporating novel M tuberculosis antigens) IGRAs and followed up for 6-12 months to establish definitive diagnoses. Sensitivity, specificity, positive and negative likelihood ratios, and predictive values of the tests were determined. FINDINGS: Of the 1060 adults enrolled in the study, 845 were included in the analyses and 363 were diagnosed with tuberculosis. Sensitivity of T-SPOT.TB for all tuberculosis diagnosis, including culture-confirmed and highly probable cases, was 81·4% (95% CI 76·6-85·3), which was higher than QFT-GIT (67·3% [62·0-72·1]). Second-generation IGRAs had a sensitivity of 94·0% (90·0-96·4) for culture-confirmed tuberculosis and 89·2% (85·2-92·2) when including highly probable tuberculosis, giving a negative likelihood ratio for all tuberculosis cases of 0·13 (95% CI 0·10-0·19). Specificity ranged from 86·2% (95% CI 82·3-89·4) for T-SPOT.TB to 80·0% (75·6-83·8) for second-generation IGRAs. INTERPRETATION: Commercially available IGRAs do not have sufficient accuracy for diagnostic evaluation of suspected tuberculosis. Second-generation tests, however, might have sufficiently high sensitivity, low negative likelihood ratio, and correspondingly high negative predictive value in low-incidence settings to facilitate prompt rule-out of tuberculosis. FUNDING: National Institute for Health Research.


description
IDEA manuscript_Whitworth et al_2ndRevision_19Sep18_Clean.docx
subject
Accepted Version
Available under Creative Commons: NC-ND 3.0

Download

Supplemental Material


Supplemental Material


Atom BibTeX OpenURL ContextObject in Span Multiline CSV OpenURL ContextObject Dublin Core Dublin Core MPEG-21 DIDL EndNote HTML Citation JSON MARC (ASCII) MARC (ISO 2709) METS MODS RDF+N3 RDF+N-Triples RDF+XML RIOXX2 XML Reference Manager Refer Simple Metadata ASCII Citation EP3 XML
Export

Downloads