Performance of commercial herpes simplex virus type-2 antibody tests using serum samples from Sub-Saharan Africa: a systematic review and meta-analysis.

Samuel Biraro; Philippe Mayaud ORCID logo; Rhoda Ashley Morrow; Heiner Grosskurth ORCID logo; Helen A Weiss ORCID logo; (2010) Performance of commercial herpes simplex virus type-2 antibody tests using serum samples from Sub-Saharan Africa: a systematic review and meta-analysis. Sexually transmitted diseases, 38 (2). pp. 140-147. ISSN 0148-5717 DOI: 10.1097/OLQ.0b013e3181f0bafb
Copy

BACKGROUND: Several commercial type-specific serologic tests are available for herpes simplex virus type 2 (HSV-2). Poor specificity of some tests has been reported on samples from sub-Saharan Africa. METHODS: To summarize the performance of the tests using samples from sub-Saharan Africa, we conducted a systematic review of publications reporting performance of commercially available HSV-2 tests against a gold standard (Western Blot or monoclonal antibody-blocking EIA). We used random-effects meta-analyses to summarize sensitivity and specificity of the 2 most commonly evaluated tests, Kalon gG2 enzyme-linked immunosorbent assay (ELISA), and Focus HerpeSelect HSV-2 ELISA. RESULTS: We identified 10 eligible articles that included 21 studies of the performance of Focus, and 12 of Kalon. The primary analyses included studies using the manufacturers' cut-offs (index value = 1.1). Focus had high sensitivity (random effects summary estimate 99%, 95% confidence interval [CI]: 99%-100%) but low specificity (69%, 95% CI: 59%-80%). Kalon had sensitivity of 95% (95% CI: 93%-97%) and specificity of 91% (95% CI: 86%-95%). Specificity of Focus was significantly lower (P = 0.002) among HIV-positive (54%, 95% CI: 40%-68%) than HIV-negative individuals (69%, 95% CI: 56%-82%). When the cut-off optical density index was increased above the recommended value of 1.1 to between 2.2 and 3.5, the specificity of Focus increased to 85% (95% CI: 77%-92%). CONCLUSIONS: Sensitivity and specificity of HSV-2 tests used in sub-Saharan Africa vary by setting, and are lower than reported from studies in the United States and Europe. Increasing the cut-off optical density index may improve test performance. Evaluation of test performance in a given setting may help deciding which test is most appropriate.

Full text not available from this repository.

Atom BibTeX OpenURL ContextObject in Span Multiline CSV OpenURL ContextObject Dublin Core Dublin Core MPEG-21 DIDL EndNote HTML Citation JSON MARC (ASCII) MARC (ISO 2709) METS MODS RDF+N3 RDF+N-Triples RDF+XML RIOXX2 XML Reference Manager Refer Simple Metadata ASCII Citation EP3 XML
Export

Downloads